Effects of external disturbances on the performance of an axial cooling fan

Authors

DOI:

https://doi.org/10.14232/analecta.2019.1.48-55

Keywords:

aerodynamic forces, CFD, covering, fan, free stream velocity

Abstract

In this study flow around an axial flow fan is investigated by the means of CFD computations using the commercial software package, ANSYS Fluent. The rotation speed of the impeller was set to the constant value of n = 2500min-1. The results obtained from the computation are validated against those from measurements; good agreements can be seen. The effects of two different external disturbances are analysed. First, the fan was place into a uniform stream where the free stream velocity is varied between U = 0 and 100 km/h. After that, a computation is carried out for U = 0 km/h where the half of the suction side of the fan was covered by a flat plate. The results showed that the fluid pressure and the aerodynamic force increases with the free stream velocity. Asymmetric pressure and fluid force distribution was identified when suction side of the fan was partially covered.

Downloads

Download data is not yet available.

References

[1] Park, M.-J., Lee, D.-J.: Sources of broadband noise of an automotive cooling fan. Applied Acoustics 118 (2017), 66–75.
[2] Lallier-Daniels, D., Piellard, M., Coutty, B., Moreau, S.: Aeroacoustic study of an axial engine cooling module using lattice-Boltzmann simulations and the Ffowcs Williams and Hawkings’ analogy. European Journal of Mechanics B/Fluids 61 (2017), 244–254.
[3] Ffowcs Williams, J.E., Hawkings, D.L.: Sound generation by turbulence and surfaces in arbitrary motion. Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences 264 (1969), 321–342.
[4] Pogorelov, A., Meinke, M., Schröder, W.: Effects of tip-gap width on the flow field in an axial fan. International Journal of Heat and Fluid Flow 61 (2016), 466–481.
[5] Ambdekar, T.C., Barve, S.B., Kothavale, B.S., Dhokane, N.T.: Design and analysis of engine cooling fan. International Journal of Current Engineering and Technology 3 (special issue, 2014), 114-118.
[6] Ye, X., Li, P., Li, C., Ding, X.: Numerical investigation of blade tip grooving effect on performance and dynamics of an axial flow fan. Energy 82 (2015), 556–569.
[7] Zhang, L., Jin, Y., Jin, Y.: Effect of Tip Flange on Tip Leakage Flow of Small Axial Flow Fans. Journal of Thermal Science 23 (2014), 45–52.

Downloads

Published

2019-06-25

How to Cite

Dorogi, D., Bolló, B., & Szabó, S. (2019). Effects of external disturbances on the performance of an axial cooling fan. Analecta Technica Szegedinensia, 13(1), 48–55. https://doi.org/10.14232/analecta.2019.1.48-55

Issue

Section

Articles